Product Overview
Item
|
Description
|
Product Name
|
Frequency Inverter/ AC Drive
|
Model Number
|
V9-H-4TxxG/xxL
|
Power Range
|
0.75kW-630kW
|
Rated Input Voltage
|
3 phase 380V/480V
|
Rated Output Voltage
|
3 phase 0 to rated input voltage
|
Input Frequency
|
50Hz/60Hz
|
Adaptable Motor
|
Asynchronous Motor, Synchronous Motor
|
Control Mode
|
V/F Control, Vector Control, Sensorless Vector Control, Sensor Vector Control, Vector Torque Control
|
Communication
|
Modbus 485 RTU, CANOpen, Profibus-DP, Profinet
|
IP Class
|
Standard IP20
|
Overload Capacity
|
150% 1 minute, 180% 10 seconds, 200% 0.5 second, interval: 10 minutes (inverse time lag feature)
|
Feature
■
Fast and accurate motor parameter self-learning, suitable for a variety of motors: synchronous/asynchronous/reluctance/high-speed/torque motor, VF vector encoder closed loop integrated
■
Asynchronous and non-inductive VF control, 200% torque output at 0.25Hz in electric state, 200% torque output at 1Hz in power generation state
■
Good voltage and current control, high speed, high frequency, deep field weakening, wave-by-wave current limiting, multiple protections
■
Modular compact structure design, high power density
■
Support multiple encoders and multiple high-speed communication protocols
■
Integrated drive and control, expandable PLC and motion control card
■
Multiple language keyboard, friendly interface, reliable and easy to use
Model
Explanation
Pro
duct Catalogue
V9−H−4T
□□□
G
Three-phase 400V constant torque / heavy duty
;
application
Power(kW)
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
110
|
Motor power (kW)
|
0.75
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
110
|
Output
|
Voltage (V)
|
3-phase 0 -rated input voltage
|
Rated
current (A)
|
2.5
|
3.8
|
5.5
|
9
|
13
|
17
|
24
|
30
|
39
|
45
|
60
|
75
|
91
|
112
|
150
|
176
|
210
|
Overloa capability
|
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
|
Input
|
Rated
voltage / frequency
|
3-phase 380V-480V;50Hz/60Hz
|
Allowabl
voltage
|
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
|
Rated
current (A)
|
2.8
|
4.2
|
6.1
|
10
|
15
|
19
|
26
|
33
|
43
|
50
|
66
|
83
|
100
|
123
|
165
|
194
|
231
|
Brake unit
|
Standard built-in
|
Built-in brake unit is optional
|
Protection level
|
IP20
|
Cooling method
|
Self−cooling
|
Forced cooling
|
Power(kW)
|
132
|
160
|
185
|
200
|
220
|
250
|
280
|
315
|
355
|
400
|
450
|
500
|
560
|
630
|
Motor power (kW)
|
132
|
160
|
185
|
200
|
220
|
250
|
280
|
315
|
355
|
400
|
450
|
500
|
560
|
630
|
Output
|
Voltage (V)
|
3-phase 0 -rated input voltage
|
Rated current (A)
|
253
|
304
|
350
|
380
|
426
|
470
|
520
|
600
|
650
|
690
|
775
|
860
|
950
|
1100
|
Overload
capability
|
150% 1min,180% 10s, 200% 0.5s,10min interval (Inverse-time characteristic)
|
Input
|
Rated
voltage / frequency
|
3-phase 380V-480V;50Hz/60Hz
|
Allowable
voltage
|
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
|
Rated
current (A)
|
232
|
282
|
326
|
352
|
385
|
437
|
491
|
580
|
624
|
670
|
755
|
840
|
920
|
1050
|
Brake unit
|
External braking unit needed
|
Protection level
|
IP20
|
Cooling method
|
Forced cooling
|
Note
:
*
0.75kW
~
15kW
:
no built-in DC reactor ;
18.5kW
~
110kW
:
optional DC reactor ;
132kW
~
160kW
:
standard built-in DC reactor ;
185kW
~
500kW
:
standard external DC reactor
560kW
~
630kW
:
standard built-in AC input reactor
Higher power level product can be customized
220V, 690V, 1140V
and other voltage level inverters can be
;
customized
V9−H−4T
□□□
L
;
Three−phase 400V Variable torque/light−duty
;
application
Power(kW)
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
110
|
132
|
Motor power (kW)
|
1.5
|
2.2
|
3.7
|
5.5
|
7.5
|
11
|
15
|
18.5
|
22
|
30
|
37
|
45
|
55
|
75
|
90
|
110
|
132
|
Output
|
Voltage(V)
|
3-phase 0 -rated input voltage
|
Rated current (A)
|
3.3
|
5
|
7.5
|
11
|
17
|
22
|
29
|
35
|
45
|
57
|
70
|
91
|
110
|
144
|
180
|
216
|
242
|
Overload capability
|
120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
|
Input
|
Rated voltage
/frequency
|
3-phase 380V-480V;50Hz/60Hz
|
Allowable
voltage
|
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
|
Rated current (A)
|
3.6
|
5.5
|
8.3
|
12
|
19
|
25
|
32
|
39
|
50
|
61
|
77
|
100
|
121
|
158
|
198
|
238
|
266
|
Brake unit
|
Standard built-in
|
Built-in brake unit is optional
|
Protection level
|
IP20
|
Cooling method
|
Self
−cooling
|
Forced cooling
|
Power(kW)
|
160
|
185
|
200
|
220
|
250
|
280
|
315
|
355
|
400
|
450
|
500
|
560
|
630
|
710
|
Motor power (kW)
|
160
|
185
|
200
|
220
|
250
|
280
|
315
|
355
|
400
|
450
|
500
|
560
|
630
|
710
|
Output
|
Voltage (V)
|
3-phase 0 -rated input voltage
|
Rated current
(A)
|
325
|
365
|
405
|
440
|
495
|
547
|
610
|
695
|
770
|
866
|
950
|
1100
|
1200
|
1300
|
Overload capability
|
120% 1min,160% 0.5s,10min interval (Inverse-time characteristic)
|
Input
|
Rated voltage
/frequency
|
3-phase 380V-480V;50Hz/60Hz
|
Allowabl
voltage
|
323V-528V;degree of voltage unbalance:≤3%;allowable frequency fluctuations:±5%
|
Rated
current
(A)
|
282
|
326
|
352
|
385
|
437
|
491
|
580
|
670
|
755
|
840
|
920
|
1050
|
1150
|
1250
|
Brake unit
|
External braking unit needed
|
Protection level
|
IP20
|
Cooling method
|
Forced cooling
|
200kW
~
560kW: standard external DC reactor ;
Note: * 1.5kW - 18.5kW: no built-in DC reactor ;
22kW
~
132kW: optional DC reactor ;
160kW
~
185kW: standard built-in DC reactor ;
630kW
~
710kW: standard built-in AC input reactor
Higher power level product can be customized ;
220V, 690V, 1140V and other voltage level inverters can be customized
Technical Specification
Control characteristics
|
Control ;
mode
|
Sensor-less control
|
Sensor control
|
Applicable motor type
|
S
ynchronous motor
Asynchronous motor
|
S
ynchronous motor
Asynchronous motor
|
Starting torque
|
●
Asynchronous
;
motor:
200% of rated torque at 0.25Hz
●
S
ynchronous
;
motor:
150% of rated torque at 1.5% of rated speed
|
200% of rated torque at 0 speed
|
Speed regulation range
|
1:
2
00
|
1:
5000
|
Steady speed precision
|
± 0.5%
|
± 0.
0
2%
|
Maximum speed
|
VF control
: 600
Hz
Vector control:
600 Hz
;
Note
: H
igher frequency products can be customized
|
600
Hz
Note
: H
igher
frequency
products can be customized
|
Torque control
|
Y
|
Y
|
Torque
control
precision
|
±5%
|
±
3
%
|
Torque response time
|
<
20ms
|
<
10ms
|
Positioning control
|
N
|
Y
|
Positioning
precision
|
N
|
±
1
;
pulse
|
Product function
|
Key function
|
Torque limit, speed control, positioning control, motor ;
auto tune
, ;
deep ;
flux-weakening
;
control, current limit control, over
-
voltage control, under
-
voltage control, ;
motor ;
speed tracing function, droop control, oscillation suppression, random carrier frequency, inertia auto-tune, et
c.
|
Speed reference source
|
Modbus communication, Keypad
, ;
external digital input
, analog
;
AI1/AI2/AI3
, ;
high speed pulse input, ;
simple PLC, PID, ;
CAN, PROFIBUS DP, PROFINET
, ;
etc
.
|
Dynamic
brak
e
|
Brak
e
unit action voltage: 650 ~ 750V
.
The brak
e
unit can be built-in for
110kW
and below equipment
●
0.75
~
15
kW
: brak
e
unit i
s built- in as standard.
●
18.5
~110kW
:
brake unit is bu
ilt- in as optional.
|
Communication
|
Built-in
M
odbus-RTU communication, the maximum distance up to 500 meters.
|
Keypad
|
LED Keypad and LCD Keypad are optional
the Keypad can be used as ;
remote-control box ;
via straight-through wired cable.
;
|
Common DC bus
|
Support common DC bus ;
directly
|
In
dependent air duct
|
All series product adopts independent duct design
|
Protection functio
n
|
Power supply under
-
voltage, over
-
current protection, over
-
voltage protection, ;
auto
-
tune fault
, module protection, heat-sink over
temperature
;protection, drive overload protection, motor overload protection, peripheral protection, current ;
abnormal
;detection, output short
-
circuit
;
to
;ground protection, EEPROM abnormal detection, temperature sampling disconnection, encoder disconnection, analog input abnormal detection, motor over
temperature
, communication ;
fault
, hardware overload protection, etc.
|
Efficiency
|
At rat
ing condition
:
●
0.7
5
kW to ;
7.5kW
: ;
≥93%
●
11kW to ;
45kW
: ;
≥95%
●
55kW and ;
higher ;
power class
:
;≥98%
|
Environment
|
Operating site
|
●
Install vertically in a well-ventilated electrical cabinet. Horizontal or other installation methods are not allowed.
●
The cooling medium is air.
● Installed in an environment free from direct sunlight, dust, corrosive gases, flammable gases, no oil mist, no steam, no dripping.
|
Ambient temperature
|
●
−10
~
+40℃
●
D
erating use when the temperature between 40 to 50
℃
, t
he rated output current is reduced by 1% for every 1 °C increasing.
|
Humidity
|
5
~
95%
, ;
no condensation is allowed.
|
Altitude
|
●
0
~
2000
;
meters
●
D
erating use when the altitude over 1000 meters
, t
he rated output current is reduced by 1% for every 100-meter rising.
|
Vibration
|
●
3.5 m/s
2
, ;
2
~
9Hz
●
10 m/s
2
, ;
9
~
200Hz
●
15 m/s
2
, ;
200
~
500Hz
|
Storage temperature
|
−40
~
+70℃
.
|
I
nstallation dimension
V9
−H−4T
7.5G/11L
and
below power class
V9−H−4T11G/15L and above power class
Voltage
|
Model
|
Outline and mounting dimension (
mm
)
|
Weight
(
kg
)
|
W
|
H
|
D
|
W1
|
H1
|
T
1
|
Mounting hole
diameter ;
d
|
400V
|
V
9
−H−4T0.75G/1.5L
|
118
|
190
|
155
|
105
|
173
|
3
|
5.5
|
1.5
|
V
9
−H−4T1.5G/2.2L
|
118
|
190
|
175
|
105
|
173
|
4
|
5.5
|
2.
6
|
V
9
−H−4T2.2G/3.7L
|
V
9
−H−4T3.7G/5.5L
|
V
9
−H−4T5.5G/7.5L
|
155
|
249
|
185
|
136
|
232
|
8
|
5.5
|
3
|
V
9
−H−4T7.5G/11L
|
V
9
−H−4T11G/15L
|
198
|
299
|
190
|
160
|
283
|
1.2
|
6
|
8
|
V
9
−H−4T15G/18.5L
|
V
9
−H−4T18.5G/22L
|
223
|
348
|
208
|
195
|
335
|
1.5
|
6
|
10
|
V
9
−H−4T22G/30L
|
V
9
−H−4T30G/37L
|
264
|
430
|
235
|
230
|
418
|
1.5
|
7
|
18
|
V
9
−H−4T37G/45L
|
V
9
−H−4T45G/55L
|
305
|
545
|
270
|
245
|
523
|
1.5
|
10
|
35
|
V
9
−H−4T55G/75L
|
V
9
−H−4T75G/90L
|
338
|
580
|
310
|
270
|
560
|
1.5
|
10
|
52
|
V9−H−4T90G
/110L
|
V
9
−H−4T110G
/132L
|
V
9
−
H−4T132G
/
160L
|
400
|
917
|
323
|
320
|
890
|
3.0
|
12
|
7
5
|
V
9
−
H−4T160G
/18
5L
|
V
9
−
H−4T185G
/
200L
|
540
|
890
|
385
|
370
|
855
|
4.0
|
14
|
85
|
V
9
−
H−4T200G
/
220L
|
V
9
−
H−4T220G
/
250L
|
540
|
890
|
416
|
370
|
855
|
4.0
|
14
|
85
|
V
9
−
H−4T250G
/
280L
|
700
|
1010
|
385
|
520
|
977
|
4.0
|
14
|
125
|
V
9
−
H−4T280G
/
315L
|
V
9
−
H−4T315G
/
355L
|
700
|
1010
|
418.5
|
520
|
977
|
4.0
|
14
|
125
|
V
9
−
H−4T355G
/
400L
|
810
|
1358
|
425
|
520
|
1300
|
4.0
|
14
|
215
|
V
9
−
H−4T400G
/
450L
|
810
|
1358
|
425
|
520
|
1300
|
4.0
|
14
|
215
|
V
9
−
H−4T450G
/
500L
|
V
9
−
H−4T500G/560L
|
Applications
Representative Industry
Печать упаковки, нефтехимии,
текстиля, кабельного оборудования, упаковки для пищевых продуктов, электромобилей, пластиковых машин, металла;
Продукты Оборудование, центрифуги и высокотехнологичные приложения, требующие управления вектором или крутящим моментом с обратной связью.